H-BOX "multi zone" Specifications

PERFORMANCE

Max pressure

Primary circuit
Secondary circuit
3,400kPa
1,000kPa

Max operating pressure

Secondary circuit 500kPa

Fluid temperature range

  5 - 70 degC

Primary circuit flow rate
required per H-BOX unit

  0.08 l/s (HBOX6)
0.1l/s (HBOX10)

Connections

Primary circuit (Inlet / Outlet)
Secondary circuit outlets
Secondary circuit inlet

25mm BSP
15mm CU
20mm CU

Weight (dry)

  20kg (HBOX6)
25kg (HBOX10)

Dimensions

H x D x W 600 x 170 x 600mm (HBOX6)
600 x 170 x 800mm (HBOX10)

A tempering valve may be incorporated for warm water circulation. Please contact us to discuss your requirements.

 

Electric Supply

  10A GPO, 230 - 240VAC 50Hz

Power Consumption

  64 - 158Watts

Current Consumption

 

Max 0.7A

 